| 4.1 | electric propulsion installation complies with Part 3 of these Standards | |
| electric propulsion installation complies with British Standards | ||
| electric propulsion installation complies with IEE Regulations | ||
| 4.2 | batteries stowed in accordance with IEE Regulations | |
| batteries adequately ventilated | ||
| 4.3 | propulsion motor securely installed | |
| 4.4 | propulsion motor has an effective means of reversing | |
| propulsion motor has an effective means of reversing operable from steering position | ||
| 4.5 | master switch fitted | |
| master switch disconnects supply to propulsion motor | ||
| master switch operable from steering position | ||
| 4.6 | charging leads have 3 core flexible cable | |
| charging leads of adequate current carrying capacity | ||
| charging leads of suitable construction and grade | ||
| charging leads splash-proof to BS EN 60309 Part 2 | ||
| 4.7 | charging panel adequately ventilated | |
| charging panel has a positive switch fitted | ||
| charging panel has a warning light fitted | ||
| 4.8 | battery-exhaust ventilation fan on automatic switch | |
| 4.9 | motor compartment adequately ventilated | |
| controller compartment adequately ventilated | ||
| All checklist items relevant to the boat's installations are mandatory passes for non-private vessels | ||